Engineered for exceptional rotational stability, this unique C-loop design provides 300% more radial compression force than traditional hydrophobic acrylic IOLs.1
The AccuSet™ haptics provide an impressive 110° of capsular bag contact, which translates to 31% and 25% greater capsular bag contact than Tecnis and AcrySof IQ, respectively.2
The design provides the predictability that when the IOL reaches its final surgical position, there’s confidence that it will remain there.
1. Bozukova D, Pagnoulle C, Jerome C. Biomechanical and optical properties of 2 new hydrophobic platforms for intraocular lenses. J Cataract Refract Surg. 2013; 39:1404–1414.
2. BAUSCH + LOMB data on file: Intraocular lens design verification report. July 2016.
The AccuSet™ haptics include a unique fenestrations design which facilitate intraoperative lens manipulation. The surgeon can rotate the enVista® monofocal IOL either counterclockwise or clockwise within the capsular bag easily.
Bausch + Lomb has STORZ® surgical instruments specifically designed for the enVista® IOL platform. Explore this more at www.StorzEye.com.
Surrounding the advanced optic posteriorly is a continuous 360° square-edge design. This cryolathed, micro grooved peripheral edge helps to reduce edge glare.1 Square-edge designs have been shown to have the potential benefit of preventing PCO compared to round-edge designs.2
Feel confident in your post-op visits as the enVista® monofocal IOL has seen low long-term PCO incidence rates of just 2.2% at 3 years post-surgery.3
1. Data on File, Bausch+Lomb Inc.
2. Buehl W et al. Effect of intraocular lens design on posterior capsule opacification. J Cataract Refract Surg. 2008;34:1976-1985. ASCRS and ESCRS.
3. Tran T. Incidence of Nd:YAG capsulotomy of a hydrophobic glistening-free intraocular lens (MX60). Paper presented at XXXIII Congress of the European Society of Cataract and Refractive Surgeons (ESCRS); September 5-9, 2015; Barcelona, Spain.
The enVista® IOL TruSight™ Optic material is glistening-free and 25x harder than traditional hydrophobic acrylic lenses, built for the increased resistance to scratches and abrasions.1-3
Have peace of mind for your lens integrity during the IOL loading and insertion steps.
1. Parker et al. Safety and effectiveness of a glistening-free single-piece hydrophobic acrylic intraocular lens (enVista®). Clin Ophthalmol. 2013:7 1905–1912.
2. P. Heiner et al. Safety and effectiveness of a single-piece hydrophobic acrylic intraocular lens (enVista®) – results of a European and Asian-Pacific study. Clin Ophthalmol. 2014:8 629–635.
3. Elachchabi A, Martin P, Goldberg E, Mentak K. Nanoindentation studies on hydrophobic acrylic IOLs to evaluate surface mechanical properties. Paper presented at: XXV Congress of the European Society of Cataract and Refractive Surgeons (ESCRS); September 8-12, 2007; Stockholm, Sweden.
No more waiting around. Part of the TruSight™ Optic, the enVista® IOL StableFlex™ technology allows for the lens to have controlled and efficient unfolding within the capsular bag. The enVista® IOL enhanced material technology provides quick optic recovery times.
1. BAUSCH + LOMB data on file: Enhanced enVista® Unfolding Study Report_ENG16-067S_August 2016.
The aberration-free optic design of the enVista® IOL allows for consistent, uniform power from center to edge. It does not induce other aberrations in case of decentration or tilt.1,2 The AO Advanced Optic design provides a desirable compromise between depth of field and image quality.3
In a laboratory study using an ISO 1 cornea, the residual aberrations are higher with AcrySof IQ and Tecnis IOLs than the enVista® IOL platform. With its advanced aberration-free optic, enVista® IOL delivers increased light throughput compared to AcrySof IQ and Tecnis lenses and predictably provides exceptional image quality and contrast sensitivity regardless of pupil size.4
AcrySof is a trademark of Alcon Vision LLC. Tecnis is a trademark of Johnson & Johnson Vision Care.
1. Altmann GE, Nichamin LD, Lane SS, Pepose JS. Optical performance of 3 intraocular lens designs in the presence of decentration. J Cataract Refract Surg. 2005 Mar;31(3):574-85
2. Elachchabi A, Martin P, Goldberg E, Mentak K. Nanoindentation studies on hydrophobic acrylic IOLs to evaluate surface mechanical properties. Paper presented at: XXV Congress of the European Society of Cataract and Refractive Surgeons (ESCRS); September 8-12, 2007; Stockholm, Sweden.
3. Packer M. enVista hydrophobic acrylic intraocular lens: glistening free. Expert Review of Ophthalmology. 2015; 10:5,415-420.
4. Bausch+Lomb Data on File. Comparison of Point Spread Function (PSF). October 2017.
The eye is not a perfect optical system, due to its visual axis not passing through the center of the cornea, pupil, or lens.1 The pseudophakic eye is naturally decentered with mean pupil displacement measuring 0.37 ± 0.24 mm.2
Clinical studies demonstrate that IOL decentration is omnipresent in cataract surgery, with mean decentration from 0.24-0.53 mm.3-5
The decentration of an IOL with either positive or negative spherical aberration can induce defocus, astigmatism, and coma.
The enVista® premium monofocal IOL was designed to compensate for the eye’s natural imperfections and deliver outstanding visual outcomes to a wide range of patients.
1. Pepose JS. Crystalens AO: Outstanding Refractive Outcomes With High Quality Vision. Ophthalmology Management. Aug 2010.
2. Rynders M, Lidkea B, Chisholm W, Thibos L. Statistical distribution of foveal transverse chromatic aberration, pupil centration, and angle in a population of young adults. J Opt Soc Am. 1995;12(10):2348-2357.
3. Oshika T., et al. Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration. Br J Ophthalmol 2007;91:185-188.
4. Rosales P, Marcos S. Phakometry and lens tilt and decentration using a custom developed Purkinje imaging apparatus: validation and measurements. J Opt Soc Am A Opt Image Sci Vis. 2006 ;23(3):509-520.
5. Baumeister M, Neidhardt B, Strobel J, Kohnen T. Tilt and decentration of three-piece foldable high-refractive silicone and hydrophobic acrylic intraocular lenses with 6-mm optics in an intraindividual comparison. Am J Ophthalmol. 2005;140(6):1051-1058.
There are multiple delivery options to choose from for enVista® IOL.
The Storz BLIS® delivery system uses a re-usable inserter. The injector body and plunger are designed with durable titanium material with a screw-type design to allow for consistent, predictable lens delivery. The disposable cartridge tips allow for 2.2 – 2.6 mm incision sizes.
Looking for less manual lens handling? Use the preloaded SimplifEye™ delivery system. It uses a snap in shuttle (containing the enVista® IOL) and disposable screw-type inserter.
Prefer push-type inserters to screw-type? The INJ100 delivery system utilizes a disposable push-type inserter with a silicone plunger tip for smooth, single-hand delivery into 2.2 – 2.6 mm incision sizes.
enVista® IOL excels in stable performance, predictability, and visual clarity with a unique design and proprietary cryolathing manufacturing process. With its aberration-free optic and glistening-free performance, make the enVista® IOL premium monofocal IOL your clear choice for IOL excellence.1
1. enVista® Directions for Use.
Legal Notice & Privacy Policy
For Professional Use Only. ®/™ are trademarks of Bausch + Lomb Corporation or its affiliates. Any other product/brand names and/or logos are trademarks of the respective owners. Bausch + Lomb Corporation, Vaughan, Ontario, L4K 4B4. ©2023 Bausch + Lomb Corporation.